Features
- Measurement and alarm of voltage, current, temperature, and power use by each phase with one module
- Easy installation and convenient usage
- Real-time power monitoring and display of electric charges imposed/expected
- Setup of range of alarm by load and saving
- Power monitoring available for all loads regardless of number of loads
- Wired/wireless LAN data communication enabling distant and remote monitoring
- Measurement of current, voltage, active power, amount of power, power factor, line voltage, phase voltage, temperature, harmonics, current rise, etc.
- Collects at least 200ms (0.2 seconds) of data through 1/4000 samplings per second
- Collect date per minimum of one second using the cloud EMS system
- Fire hazard prevention with busbar temperature sensors
AC Meter Specifications
- Input Power DC 8~28V
-
Voltage Measurement
- Measurement Range 0 ~ 600 VAC(Line Voltage) Phase Voltage: V1, V2, V3-N Line Voltage: V1-V2, V2-V3, V3-V1
- Frequency 50 ~ 60Hz
- Measurement Method Jig Pin Direct Connection
-
Current Measurement
- Measurement Range 0 ~125A, 0 ~250A, 0 ~ 400A
- Measurement Method IMC-Hall Current Sensor
-
Temperature Measurement
- Measurement Range 0℃ ~ 60℃ (Based on Bus-bar)
-
Environment
- Operating Temperature -20°C ~ 60°C
- Storage Temperature -40°C ~ 70°C
-
Other Functions
- Communication Interface RS-485 x 1(RJ45, UTP Cable)
Single Phase
3-Phase
3-Phase 4-Wire
DC Meter Specifications
- Input Power DC 8~28V
-
Voltage Measurement
- Measurement Range -50~50VDC, -600~600VDC
- Measurement Method Direct Jig Pin Contact
-
Current Measurement
- Measurement Range 0 ~125A, 0 ~250A, 0 ~ 400A
- Measurement Method IMC-Hall Current Sensor
-
Temperature Measurement
- Measurement Range 0°C ~ 60°C (Based on Bus-bar)
-
Environment
- Operating Temperature -20°C ~ 60°C
- Storage Temperature -40°C ~ 70°C
-
Other Functions
- Communication Interface RS-485 x 1(RJ45, UTP Cable)
Part Number
Part Number
A-B C-D
Ex. 1 SEM-125 FB -2P
Ex. 2 SEMDC-125 M5 -2P
- A METER TYPE
- SEM (Busbar type/AC), SEMDC (Busbar type/DC)
- B Ampere Rating
- 125 (125A), 250 (250A), 400 (400A)
- C Busbar (Bottom-Module) Specification
- Basic: Leave Blank for Primary Side
- FB (Breaker Height Difference), M5 (Breaker Connection Hole), M8 (Breaker Connection Hole)
- D Phase
- 2P (Single Phase), 3P (3-Phase 3-Wire), 4P (4-Phase 4-Wire)
- Status Indicator
- Part Number
- Product Name
- Current Capacity
- Circuit Connection Terminal
- Example of AC Installation
- Example of DC Installation
Installation Instruction
- 1. Prepare modules
- 2. Select 1st or 2nd position for the bottom-module breaker
- 3. Install bottom-module
- 4. Install top-module
- 5. Assemble top-cover
- 6. Connect smart-eye communication cable
- 7. Connect G/W communication cable
- 8. Connect monitor communication cable
- 9. Assembly and installation completed